Technical InformationOperating InstructionsSyncBox PTPv2AHS/DHS

Página 2

Precision Time Protocol (PTP) / IEEE1588v2PTP/IEEE1588 is a time synchronization protocol that offers sub-microsecondaccuracy over a s

Página 3 - Table of Contents

General InformationThe eurocard TSU-V2 acts as a standalone single board computer including networkinterface card (10/100MBit) with integrated

Página 4

Functionality in Master SystemsAfter power up, the module accepts the absolute time information (PTP seconds) of areference time source (GPS controlle

Página 5 - Quick Start Guide

The WEB interfaceConnect to the web interface by entering the following address into the addressfield of your web browser:http://198.168.10.10 (You ne

Página 6 - The Modular System SyncBox

Configuration: Main MenuAfter entering the right password, the main menu page shows up. This pagecontains an overview of the m

Página 7

Configuration: EthernetIn the network configuration all parameters related to the network interfaces can bechanged. In the first section you can chang

Página 8 - RS232 TERM

If there is a DHCP (Dynamic Host Configuration Protocol) server available in yournetwork, the LANTIME system can obtain its IPv4 settings automaticall

Página 9

Configuration: StatisticsStatistical InformationIn the first section a graphical diagram shows the running synchronization process.PTP is storing this

Página 10

Configuration: ManualThis page gives you access to the documents stored on your SyncBox, especiallythe manuals and your own notes. The two lists inclu

Página 11 - General Information

Configuration: PTPIn the PTP configuration all parameters related to the PTP protocol can bemonitored and changed. With the

Página 12

ImpressumMeinberg Funkuhren GmbH & Co. KGAuf der Landwehr 22D-31812 Bad PyrmontTelefon: +49 (0) 52 81 / 9309-0Telefax: +49 (0) 52 81 / 9309-30Inte

Página 13 - The WEB interface

Please keep in mind that peer-delay measurements are not supported when operatingin Unicast mode.A domain is a logical grouping of clocks that synchro

Página 14 - Configuration: Main Menu

The Command Line InterfaceThe command line interface (CLI) can be used within a TELNET, SSH or serialTerminal session. After login, just enter “setup”

Página 15 - IPv4 addresses and DHCP

CLI EthernetIn the network configuration all parameters related to the network interfaces can bechanged. In the first section you can change the hostn

Página 16 - Configuration: Local

CLI PTP parametersIn the PTP configuration all parameters related to the PTP protocol can bemonitored and changed. The “Profil

Página 17 - Statistical Information

Attachment: Technical InformationTechnical SpecificationsHOUSING: Metal desktop case, DIN Mounting Rail125 mm x 115 mm x 189 mm (W x H x D)PROTECTION

Página 18 - Configuration: Manual

Safety instructions for building-in equipmentThis building-in equipment has been designed and tested in accordance with therequirements of Standard

Página 19 - Configuration: PTP

Power supplyThe variant DHS is designed for operation with a DC (18 V to 72 V, DC-insulation1.5 kV). The voltage feed is done through 3 pol DFK connec

Página 20

Third party softwareThe SYNCBOX network timeserver is running a number of software productscreated and/or maintained by open source p

Página 21 - The Command Line Interface

Network Time Protocol Version 4 (NTP)The NTP project, lead by David L. Mills, can be reached in the internet atwww.ntp.org

Página 22 - CLI Ethernet

GNU General Public License (GPL) GNU GENERAL PUBLIC LICENSE Version 2, June 1991 Copyright (C) 1989, 1991 Free Software Foundation, Inc.

Página 23 - CLI PTP parameters

Table of ContentsQuick Start Guide... 5PTPv2 Sl

Página 24 - Front Panel connectors

is covered only if its contents constitute a work based on theProgram (independent of having been made by running the Program).Whether that is true de

Página 25 - CE-Label

The source code for a work means the preferred form of the work formaking modifications to it. For an executable work, complete sourcecode means all

Página 26 - Power supply

countries not thus excluded. In such case, this License incorporatesthe limitation as if written in the body of this License. 9. The Free Software F

Página 27 - Operating System GNU/Linux

CE-Label... 24Power supply...

Página 28

Quick Start GuideOne minute after power up you can connect via a null modem cable a serialterminal from your PC. While booti

Página 29

PTPv2 Slave with high accuracy OscillatorThe SyncBox provides a high precision time base (OCXO HQ) with multipleoutputs for 10MHz

Página 30

Changes in the receiver status, errors or other important events are logged on the localLinux system.PTP Status LEDs „MST“ und „SLV“To get the time fr

Página 31

OUT0 active: 1OUT1 active: 1When outputs will be enabled can be set up in this file. By default all outputs will beenabled after booting the SyncBox (